Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Time and Frequency
  • General frequency source
  • CP-E-01
  • 1 MHz to <10 MHz
2.6 x 10-11LaboratoryActive
  • 10 MHz to 350 MHz
1.2 x 10-11LaboratoryActive
  • Frequency counter or frequency meter
  • CP-E-09
  • 1 MHz
1.6 x 10-11LaboratoryActive
  • 5 MHz
1.6 x 10-11LaboratoryActive
  • 10 MHz
1.6 x 10-11LaboratoryActive
  • 1 kHz to 1 MHz
1.7 x 10-10LaboratoryActive
  • >1 MHz to 100 MHz
3.3 x 10-11LaboratoryActive
  • >100 MHz to 350 MHz
4.6 x 10-11LaboratoryActive
  • Time Interval – Stopwatches and timers
  • CP-E-13
  • 20 minutes to 100 hours
0.48 sLaboratoryActive
  • Time Interval – Local clock
  • CP-E-15
  • 24 hours
0.76 sLaboratoryActive
  • Time scale difference - Local clock vs. UTC
  • ± 5 minutes
0.76 sLaboratoryActive
  • Non-contact tachometer
  • Procedure CP-E-27 Calibration of Non Contact Tachometers
  • 30.000 rpm to 99.999 rpm
0.0018 rpmLaboratoryActive
  • 100.00 rpm to 999.99 rpm
0.0060 rpmLaboratoryActive
  • 1,000.0 rpm to 9,999.9 rpm
0.058 rpmLaboratoryActive
  • 10,000 rpm to 99,999 rpm
0.58 rpmLaboratoryActive
  • 100,000 rpm to 199,800 rpm
5.8 rpmLaboratoryActive
Mass and Balance
  • Mass/ Mass Standards
  • CP-M-02 “Calibration of Mass Standards” and CP-M-03 “Weighing Designs”
  • 500 kg
4.9 gLaboratoryActive
  • 200 kg
1.9 gLaboratoryActive
  • 100 kg
0.25 gLaboratoryActive
  • 50 000 g
80 mgLaboratoryActive
  • 20 000 g
10 mgLaboratoryActive
  • 10 000 g
1.6 mgLaboratoryActive
  • 5 000 g
0.80 mgLaboratoryActive
  • 2 000 g
0.30 mgLaboratoryActive
  • 1 000 g
0.16 mgLaboratoryActive
  • 500 g
0.080 mgLaboratoryActive
  • 200 g
0.030 mgLaboratoryActive
  • 100 g
0.016 mgLaboratoryActive
  • 50 g
0.010 mgLaboratoryActive
  • 20 g
0.0080 mgLaboratoryActive
  • 10 g
0.0060 mgLaboratoryActive
  • 5 g
0.0050 mgLaboratoryActive
  • 2 g
0.0040 mgLaboratoryActive
  • 1 g
0.0030 mgLaboratoryActive
  • 0.5 g
0.0025 mgLaboratoryActive
  • 0.2 g
0.0020 mgLaboratoryActive
  • 0.1 g
0.0016 mgLaboratoryActive
  • 0.05 g
0.0012 mgLaboratoryActive
  • 0.02 g
0.0010 mgLaboratoryActive
  • 0.01 g
0.0010 mgLaboratoryActive
  • 0.005 g
0.0010 mgLaboratoryActive
  • 0.002 g
0.0010 mgLaboratoryActive
  • 0.001 g
0.0010 mgLaboratoryActive
  • Mass/ Electronic Balances
  • CP-M-01 “Calibration of NAWI’s”, Weights are available in OIML Classes: • E2: 1 mg to 5 kg; max grouped load 11.11 kg. • F1: 1 mg to 50 kg; max grouped load 171.1 kg
  • 170 kg
740 mgCustomer premisesActive
  • 100 kg
660 mgCustomer premisesActive
  • 50 kg
140 mgCustomer premisesActive
  • 20 kg
46 mgCustomer premisesActive
  • 10 kg
25 mgCustomer premisesActive
  • 5 kg
3.8 mgCustomer premisesActive
  • 2 kg
1.5 mgCustomer premisesActive
  • 1 kg
0.76 mgCustomer premisesActive
  • 500 g
0.38 mgCustomer premisesActive
  • 200 g
0.15 mgCustomer premisesActive
  • 100 g
0.078 mgCustomer premisesActive
  • 50 g
0.046 mgCustomer premisesActive
  • 20 g
0.038 mgCustomer premisesActive
  • 10 g
0.031 mgCustomer premisesActive
  • 5 g
0.024 mgCustomer premisesActive
  • 2 g
0.018 mgCustomer premisesActive
  • 1 g
0.015 mgCustomer premisesActive
  • 500 mg
0.012 mgCustomer premisesActive
  • 200 mg
0.010 mgCustomer premisesActive
Temperature
  • Resistance thermometers with display unit
  • Comparison with platinum resistance thermometer in a bath. EMI procedure: CP-T-01
  • -80 °C to 80 °C
0.015 °CLaboratoryActive
  • >80 °C to 150 °C
0.020 °CLaboratoryActive
  • >150 °C to 250 °C
0.025 °CLaboratoryActive
  • Comparison with platinum resistance thermometers, utilizing the Zn fixed point. Applies for thermometers longer than 40 cm. EMI procedure: CP-T-01
  • >250°C to 419.527 °C (Zn fixed point)
0.025 °CLaboratoryActive
  • Comparison with platinum resistance thermometers, utilizing the Zn and Al fixed points. Applies for thermometers longer than 40 cm. EMI procedure: CP-T-01
  • >250 °C to 660.323 °C (Al fixed point)
0.025 °CLaboratoryActive
  • Comparison with platinum resistance thermometer in a block calibrator. EMI procedure: CP-T-01
  • >250 °C to 660 °C
0.15 °C to 0.27 °CLaboratoryActive
  • Thermocouples with display unit
  • Comparison with platinum resistance thermometer in a bath. EMI procedure: CP-T-01
  • -80 °C to 150 °C
0.2 °CLaboratoryActive
  • >150 °C to 250 °C
0.4 °CLaboratoryActive
  • Comparison with platinum resistance thermometer in a block calibrator. EMI procedure: CP-T-01
  • >250 °C to 660 °C
0.4 °C to 0.8 °CLaboratoryActive
  • Temperature block calibrators
  • Comparison with platinum resistance thermometer. EMI procedure: CP-T-03
  • -30 °C to 660 °C
0.2 °CLaboratoryActive
  • Platinum Resistance Thermometers
  • Comparison with platinum resistance thermometers in a bath. EMI procedure: CP-T-04
  • -80 °C to 80 °C
0.010 °CLaboratoryActive
  • >80 °C to 150 °C
0.015 °CLaboratoryActive
  • >150 °C to 250 °C
0.020 °CLaboratoryActive
  • Comparison with platinum resistance thermometers in Zn fixed point. EMI procedure: CP-T-04
  • 419.527 °C (Zn fixed point)
0.005 °CLaboratoryActive
  • Comparison with platinum resistance thermometers in Al fixed point. EMI procedure: CP-T-04
  • 660.323 °C (Al fixed point)
0.020 °CLaboratoryActive
  • Comparison with platinum resistance thermometers, utilizing the Zn fixed point. Applies for thermometers longer than 40 cm. EMI procedure: CP-T-04
  • >250°C to 419.527 °C (Zn fixed point)
0.020 °CLaboratoryActive
  • Comparison with platinum resistance thermometers, utilizing the Zn and Al fixed points. Applies for thermometers longer than 40 cm. EMI procedure: CP-T-04
  • >250 °C to 660.323 °C (Al fixed point)
0.020 °CLaboratoryActive
  • Comparison with platinum resistance thermometers in a block calibrator. EMI procedure: CP-T-04
  • >250 °C to 660 °C
0.15 °C to 0.27 °CLaboratoryActive
  • Air Temperature Sensors
  • Comparison with reference thermometer in an air chamber. EMI procedure: CP-T-02
  • 10 °C to 70 °C
0.10 °C to 0.30 °CLaboratoryActive
  • SPRT Calibration at ITS-90 Fixed Points
  • Triple point of mercury (Hg). EMI procedure: CP-T-10
  • 234.3156 K
0.6 mKLaboratoryActive
  • Triple point of water. EMI procedure: CP-T-10
  • 0.01 °C
0.3 mKLaboratoryActive
  • Melting point of Gallium (Ga) EMI procedure: CP-T-10
  • 29.7646 °C
0.6 mKLaboratoryActive
  • Freezing point of Indium (In). EMI procedure: CP-T-10
  • 156.5985 °C
1.7 mKLaboratoryActive
  • Freezing point of Tin (Sn). EMI procedure: CP-T-10
  • 231.928 °C
1.6 mKLaboratoryActive
  • Freezing point of Zinc (Zn). EMI procedure: CP-T-10
  • 419.527 °C
1.9 mKLaboratoryActive
  • Freezing point of Aluminium (Al). EMI procedure: CP-T-10
  • 660.323 °C
16 mKLaboratoryActive
  • SPRT Calibration at ITS-90 Fixed Point Sub-Ranges
  • Fixed points Hg to H2O EMI procedure: CP-T-10
  • 234.3156 K to 273.16 K
0.7 mKLaboratoryActive
  • Fixed points H2O to Ga EMI procedure: CP-T-10
  • 0.01 °C to 29.746 °C
0.7 mKLaboratoryActive
  • Fixed points Ga to In EMI procedure: CP-T-10
  • 29.7646 °C to 156.5985 °C
1.8 mKLaboratoryActive
  • Fixed points In to Sn EMI procedure: CP-T-10
  • 156.5985 °C to 231.928 °C
2.0 mKLaboratoryActive
  • Fixed points Sn to Zn EMI procedure: CP-T-10
  • 231.928 °C to 419.527 °C
3.0 mKLaboratoryActive
  • Fixed points Zn to Al EMI procedure: CP-T-10
  • 419.527 °C to 660.323 °C
3 mK to 16 mKLaboratoryActive
  • Calibration of Climatic Chambers
  • DKD-R 5-7. EMI procedure: CP-T-05
  • -40 °C to 140 °C
0.2 °CCustomer’s PremisesActive
  • Calibration of Autoclaves
  • EMI procedure: CP-T-06
  • 110 °C to 140 °C
0.2 °CCustomer’s PremisesActive
  • Base metal thermocouples
  • Comparison calibration in baths and furnaces. EMI procedure: CP-T-07
  • -70 °C to 250 °C
0.2 °C to 0.4 °CLaboratoryActive
  • >250 °C to 1100 °C
0.6 °C to 1.3 oCLaboratoryActive
  • Noble metal thermocouples
  • -50 °C to 250 °C
0.2 °C to 0.4°CLaboratoryActive
  • >250 °C to 1100 °C
0.6 °C to 1.0 °CLaboratoryActive
Humidity
  • Calibration of dew point meters for relative humidity
  • Calibration in chamber of humidity generator. EMI procedure: CP-T-02
  • 10 %rh to 95 %rh at air temperature from 10 °C to 45 °C
0.3 %rh to 1.0 %rhLaboratoryActive
  • 10 %rh to 95 %rh at air temperature from 45 °C to 70 °C
0.4 %rh to 1.6 %rhLaboratoryActive
  • Calibration of relative humidity meters for relative humidity
  • 10 %rh to 95 %rh at air temperature from 10 °C to 45 °C
0.4 %rh to 1.1 %rhLaboratoryActive
  • 10 %rh to 95 %rh at air temperature from 45 °C to 70 °C
0.5 %rh to 1.7 %rhLaboratoryActive
  • Calibration of climatic chambers, humidity measurements
  • DKD-R 5-7. EMI procedure: CP-T-05
  • 10 %rh to 90 %rh at air temperature from 10 °C to 50 °C
0.6 %rh to 2 %rhCustomer’s PremisesActive
Electrical
  • Solid state DC voltage standards
  • Procedure CP-E-03 Calibration of voltage reference standards
  • 10 V
7.3 μVLaboratoryActive
  • 1.018 V
2.6 μVLaboratoryActive
  • DC resistance standards
  • Procedure CP-E-20 Using MI 6010D Bridge and Range Extender R = Measured Value
  • 100 μΩ to <1 mΩ
8.8 ×10-6·RLaboratoryActive
  • 1 mΩ to <10 mΩ
6.6×10-6·RLaboratoryActive
  • 10 mΩ to <100 mΩ
3.4 ×10-6·RLaboratoryActive
  • 100 mΩ to <1 Ω
0.30 ×10-6·RLaboratoryActive
  • 1 Ω to 10 Ω
0.28 ×10-6·RLaboratoryActive
  • >10 Ω to <100 Ω
0.33 ×10-6 RLaboratoryActive
  • 100 Ω to <1 kΩ
0.26 ×10-6 RLaboratoryActive
  • 1 kΩ to 10 kΩ
0.27 ×10-6 RLaboratoryActive
  • Procedure CP-E-17. Using MI 6000B Bridge R = Measured Value
  • >10 kΩ to 100 kΩ
2.0 ×10-6·RLaboratoryActive
  • >100 kΩ to 1 MΩ
4.0 ×10-6·RLaboratoryActive
  • >1 MΩ to 10 MΩ
12 ×10-6·RLaboratoryActive
  • >10 MΩ to 100 MΩ
19 ×10-6·RLaboratoryActive
  • >100 MΩ to 1 GΩ
60 ×10-6·RLaboratoryActive
  • DC resistance Calibration of Resistor Decades
  • Procedure CP-E-23 Calibration of Resistors and Decade Resistors by Direct Reading R = measured resistance value
  • 0.1 Ω/step
0.05 mΩLaboratoryActive
  • 1 Ω/step
50 ×10-6·RLaboratoryActive
  • 10 Ω/step
10 ×10-6·RLaboratoryActive
  • 100 Ω/step
7.0 ×10-6·RLaboratoryActive
  • 1 kΩ/step
7.0 ×10-6·RLaboratoryActive
  • DC resistance ratio
  • Procedure CP-E-12 Calibration of DCC Resistance Bridges and Range Extender
  • 0.1:1 to 10:1
0.08 ×10-6LaboratoryActive
  • 10:1 Range Extender
2.9 ×10-6LaboratoryActive
  • 100:1 Range Extender
5.8 ×10-6LaboratoryActive
  • 1000:1 Range Extender
10 ×10-6LaboratoryActive
  • DC Voltage Calibration of Measuring Instruments
  • Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-24 Calibration of Process Calibrators U = Measured Value
  • 0 mV to 200 mV
5.8 ×10-6 U + 1.0 μVLaboratoryActive
  • >0.2 V to 2 V
5.0 ×10-6 U + 1.0 μVLaboratoryActive
  • >2 V to 10 V
3.6 ×10-6 U + 2.6 μVLaboratoryActive
  • >10 V to 22 V
3.8 ×10-6 U + 3.8 μVLaboratoryActive
  • >22 V to 220 V
5.4 ×10-6 U + 39 μVLaboratoryActive
  • >220 V to 1000 V
10 ×10-6 U + 0.31 mVLaboratoryActive
  • Procedure CP-E-06 Calibration of 8.5 digit Digital Multimeters Using MI 8000A bridge U = Measured Value
  • 0 mV to 200 mV
0.62 μVLaboratoryActive
  • >0.2 V to 2 V
0.40 ×10-6 U + 0.51 μVLaboratoryActive
  • >2 V to 10 V
0.57 ×10-6 U + 0.17 μVLaboratoryActive
  • >10 V to 30 V
1.3 ×10-6 ULaboratoryActive
  • >30 V to 300 V
1.9 ×10-6 ULaboratoryActive
  • >300 V to 1000V
6.6 ×10-6 ULaboratoryActive
  • DC Voltage Calibration of sources
  • Procedure CP-E-18 Calibration of Calibrators Procedure CP-E-24 Calibration of Process Calibrators U = Measured Value
  • 0 mV to 200 mV
3.4 ×10-6 U + 0.88 μVLaboratoryActive
  • >0.2 V to 2 V
5.4 ×10-6 U + 0.55 μVLaboratoryActive
  • >2 V to 20 V
5.6 ×10-6 U + 0.55 μVLaboratoryActive
  • >20 V to 200 V
8.3 ×10-6 U + 30 μVLaboratoryActive
  • >200 V to 1000V
11 ×10-6 U + 0.42 mVLaboratoryActive
  • Procedure CP-E-04 Calibration of High Performance Calibrators Using MI 8000A bridge U = Measured Value
  • 0 mV to 200 mV
0.62 μVLaboratoryActive
  • >0.2 V to 2 V
0.40 ×10-6 U + 0.51 μVLaboratoryActive
  • >2 V to 10 V
0.57 ×10-6 U + 0.16 μVLaboratoryActive
  • >10 V to 30 V
1.3 ×10-6 ULaboratoryActive
  • >30 V to 300 V
1.9 ×10-6 ULaboratoryActive
  • >300 V to 1000V
6.6 ×10-6 ULaboratoryActive
  • AC Voltage Calibration of Measuring Instruments
  • Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-26 Calibration of Touch Current and Protective Conductor Current Measuring Instruments U = Measured Value
  • (600 µV to 2.2 Mv) 10 Hz to 20 Hz
0.15 ×10-3 U + 1.3 μVLaboratoryActive
  • (600 µV to 2.2 Mv) >20 Hz to 40 Hz
0.11 ×10-3 U + 1.3 μVLaboratoryActive
  • (600 µV to 2.2 Mv) >40 Hz to 20 kHz
94 ×10-6 U + 1.3 μVLaboratoryActive
  • (600 µV to 2.2 Mv) >20 kHz to 50 kHz
0.14 ×10-3 U + 2.0 μVLaboratoryActive
  • (600 µV to 2.2 Mv) >50 kHz to 100 kHz
0.14 ×10-3 U + 2.5 μVLaboratoryActive
  • (600 µV to 2.2 mV) >100 kHz to 300 kHz
0.41 ×10-3 U + 4.0 μVLaboratoryActive
  • (600 µV to 2.2 mV) >300 kHz to 500 kHz
1.3 ×10-3 U + 8.0 μVLaboratoryActive
  • (600 µV to 2.2 mV) >500 kHz to 1 MHz
4.5 ×10-3 U + 8.0 μVLaboratoryActive
  • (>2.2 mV to 7 mV) 10 Hz to 20 Hz
0.12 ×10-3 U + 1.3 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >20 Hz to 40 Hz
72 ×10-6 U + 1.3 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >40 Hz to 20 kHz
69 ×10-6 U + 1.3 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >20 kHz to 50 kHz
82 ×10-6 U + 2.0 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >50 kHz to 100 kHz
87 ×10-6 U + 2.5 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >100 kHz to 300 kHz
0.23 ×10-3 U + 4.0 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >300 kHz to 500 kHz
0.75 ×10-3 U + 8.0 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >500 kHz to 1 MHz
3.5 ×10-3 U + 8.0 μVLaboratoryActive
  • (>7 mV to 22 mV) 10 Hz to 20 Hz
91 ×10-6 U + 1.3 μVLaboratoryActive
  • (>7 mV to 22 mV) >20 Hz to 40 Hz
56 ×10-6 U + 1.3 μVLaboratoryActive
  • (>7 mV to 22 mV) >40 Hz to 20 kHz
53 ×10-6 U + 1.3 μVLaboratoryActive
  • (>7 mV to 22 mV) >20 kHz to 50 kHz
69 ×10-6 U + 2.0 μVLaboratoryActive
  • (>7 mV to 22 mV) >50 kHz to 100 kHz
78 ×10-6 U + 2.5 μVLaboratoryActive
  • (>7 mV to 22 mV) >100 kHz to 300 kHz
0.17 ×10-3 U + 4.0 μVLaboratoryActive
  • (>7 mV to 22 mV) >300 kHz to 500 kHz
0.62 ×10-3 U + 8.0 μVLaboratoryActive
  • (>7 mV to 22 mV) >500 kHz to 1 MHz
2.6 ×10-3 U + 8.0 μVLaboratoryActive
  • (>22 mV to 70 mV) 10 Hz to 20 Hz
85 ×10-6 U + 1.5 μVLaboratoryActive
  • (>22 mV to 70 mV) >20 Hz to 40 Hz
52 ×10-6 U + 1.5 μVLaboratoryActive
  • (>22 mV to 70 mV) >40 Hz to 20 kHz
50 ×10-6 U + 1.5 μVLaboratoryActive
  • Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-26 Calibration of Touch Current and Protective Conductor Current Measuring InstrumentsU = Measured Value
  • (>22 mV to 70 mV) >20 kHz to 50 kHz
54 ×10-6 U + 2.0 μVLaboratoryActive
  • (>22 mV to 70 mV) >50 kHz to 100 kHz
70 ×10-6 U + 2.5 μVLaboratoryActive
  • (>22 mV to 70 mV) >100 kHz to 300 kHz
0.18 ×10-3 U + 4.0 μVLaboratoryActive
  • (>22 mV to 70 mV) >300 kHz to 500 kHz
0.33 ×10-3 U + 8.0 μVLaboratoryActive
  • (>22 mV to 70 mV) >500 kHz to 1 MHz
1.3 ×10-3 U + 8.0 μVLaboratoryActive
  • (>70 mV to 220 mV) 10 Hz to 20 Hz
64 ×10-6 U + 1.5 μVLaboratoryActive
  • (>70 mV to 220 mV) >20 Hz to 40 Hz
36 ×10-6 U + 1.5 μVLaboratoryActive
  • (>70 mV to 220 mV) >40 Hz to 20 kHz
34 ×10-6 U + 1.5 μVLaboratoryActive
  • (>70 mV to 220 mV) >20 kHz to 50 kHz
34 ×10-6 U + 2.0 μVLaboratoryActive
  • (>70 mV to 220 mV) >50 kHz to 100 kHz
60 ×10-6 U + 2.5 μVLaboratoryActive
  • (>70 mV to 220 mV) >100 kHz to 300 kHz
0.18 ×10-3 U + 4.0 μVLaboratoryActive
  • Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-26 Calibration of Touch Current and Protective Conductor Current Measuring Instruments U = Measured Value
  • (>70 mV to 220 mV) >300 kHz to 500 kHz
0.32 ×10-3 U + 8.0 μVLaboratoryActive
  • (>70 mV to 220 mV) >500 kHz to 1 MHz
1.2 ×10-3 U + 8.0 μVLaboratoryActive
  • (>220 mV to 700 mV) 10 Hz to 20 Hz
64 ×10-6 U + 1.5 μVLaboratoryActive
  • (>220 mV to 700 mV) >20 Hz to 40 Hz
37 ×10-6 U + 1.5 μVLaboratoryActive
  • (>220 mV to 700 mV) >40 Hz to 20 kHz
34 ×10-6 U + 1.5 μVLaboratoryActive
  • (>220 mV to 700 mV) >20 kHz to 50 kHz
34 ×10-6 U + 2.0 μVLaboratoryActive
  • (>220 mV to 700 mV) >50 kHz to 100 kHz
60 ×10-6 U + 2.5 μVLaboratoryActive
  • (>220 mV to 700 mV) >100 kHz to 300 kHz
0.18 ×10-3 U + 4.0 μVLaboratoryActive
  • (>220 mV to 700 mV) >300 kHz to 500 kHz
0.32 ×10-3 U + 8.0 μVLaboratoryActive
  • (>220 mV to 700 mV) >500 kHz to 1 MHz
1.2 ×10-3 U + 8.0 μVLaboratoryActive
  • Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-26 Calibration of Touch Current and Protective Conductor Current Measuring Instruments U = Measured Value
  • (>700 mV to 2.2 V) 10 Hz to 20 Hz
64 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >20 Hz to 40 Hz
37 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >40 Hz to 20 kHz
30 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >20 kHz to 50 kHz
34 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >50 kHz to 100 kHz
58 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >100 kHz to 300 kHz
0.17 ×10-3 ULaboratoryActive
  • (>700 mV to 2.2 V) >300 kHz to 500 kHz
0.29 ×10-3 ULaboratoryActive
  • (>700 mV to 2.2 V) >500 kHz to 1 MHz
1.2 ×10-3 ULaboratoryActive
  • (>2.2 V to 7 V) 10 Hz to 20 Hz
63 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >20 Hz to 40 Hz
37 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >40 Hz to 20 kHz
28 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >20 kHz to 50 kHz
36 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >50 kHz to 100 kHz
74 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >100 kHz to 300 kHz
0.18 ×10-3 ULaboratoryActive
  • (>2.2 V to 7 V) >300 kHz to 500 kHz
0.45 ×10-3 ULaboratoryActive
  • (>2.2 V to 7 V) >500 kHz to 1 MHz
1.5 ×10-3 ULaboratoryActive
  • (>7 V to 22 V) 10 Hz to 20 Hz
63 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >20 Hz to 40 Hz
38 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >40 Hz to 20 kHz
28 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >20 kHz to 50 kHz
36 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >50 kHz to 100 kHz
70 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >100 kHz to 300 kHz
0.19 ×10-3 ULaboratoryActive
  • (>7 V to 22 V) >300 kHz to 500 kHz
0.46 ×10-3 ULaboratoryActive
  • (>7 V to 22 V) >500 kHz to 1 MHz
1.5 ×10-3 ULaboratoryActive
  • (>22 V to 70 V) 10 Hz to 20 Hz
64 ×10-6 U + 1.6 μVLaboratoryActive
  • (>22 V to 70 V) >20 Hz to 40 Hz
40 ×10-6 U + 2.6 μVLaboratoryActive
  • (>22 V to 70 V) >40 Hz to 20 kHz
35 ×10-6 U + 2.9 μVLaboratoryActive
  • (>22 V to 70 V) >20 kHz to 50 kHz
40 ×10-6 U + 2.6 μVLaboratoryActive
  • (>22 V to 70 V) >50 kHz to 100 kHz
86 ×10-6 U + 1.2 μVLaboratoryActive
  • (>22 V to 70 V) >100 kHz to 300 kHz
0.19 ×10-3 ULaboratoryActive
  • (>22 V to 70 V) >300 kHz to 500 kHz
0.50 ×10-3 ULaboratoryActive
  • (>22 V to 70 V) >500 kHz to 1 MHz
1.5 ×10-3 ULaboratoryActive
  • (>70 V to 220 V) 10 Hz to 20 Hz
66 ×10-6 ULaboratoryActive
  • (>70 V to 220 V) >20 Hz to 40 Hz
42 ×10-6 ULaboratoryActive
  • (>70 V to 220 V) >40 Hz to 20 kHz
37 ×10-6 ULaboratoryActive
  • (>70 V to 220 V) >20 kHz to 50 kHz
51 ×10-6 ULaboratoryActive
  • (>70 V to 220 V) >50 kHz to 100 kHz
89 ×10-6 ULaboratoryActive
  • (>220 V to 700 V) 40 Hz to 20 kHz
34 ×10-6 U + 30 μVLaboratoryActive
  • (>220 V to 700 V) >20 kHz to 50 kHz
0.15 ×10-3 U + 7.2 μVLaboratoryActive
  • (>220 V to 700 V) >50 kHz to 100 kHz
0.86 ×10-3 U + 1.2 μVLaboratoryActive
  • (>700 V to 1000 V) 40 Hz to 20 kHz
34 ×10-6 U + 13 μVLaboratoryActive
  • AC voltage Calibration of sources
  • Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
  • (600 µV to 2.2 mV) 10 Hz to 20 Hz
0.15 ×10-3 U + 1.3 μVLaboratoryActive
  • (600 µV to 2.2 mV) >20 Hz to 40 Hz
0.11 ×10-3 U + 1.3 μVLaboratoryActive
  • (600 µV to 2.2 mV) >40 Hz to 20 kHz
94 ×10-6 U + 1.3 μVLaboratoryActive
  • (600 µV to 2.2 mV) >20 kHz to 50 kHz
0.14 ×10-3 U + 2.0 μVLaboratoryActive
  • (600 µV to 2.2 mV) >50 kHz to 100 kHz
0.14 ×10-3 U + 2.5 μVLaboratoryActive
  • (600 µV to 2.2 mV) >100 kHz to 300 kHz
0.41 ×10-3 U + 4.0 μVLaboratoryActive
  • (600 µV to 2.2 mV) >300 kHz to 500 kHz
1.3 ×10-3 U + 8.0 μVLaboratoryActive
  • (600 µV to 2.2 mV) >500 kHz to 1 MHz
4.5 ×10-3 U + 8.0 μVLaboratoryActive
  • (>2.2 mV to 7 mV) 10 Hz to 20 Hz
0.12 ×10-3 U + 1.3 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >20 Hz to 40 Hz
72 ×10-6 U + 1.3 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >40 Hz to 20 kHz
69 ×10-6 U + 1.3 μVLaboratoryActive
  • Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
  • (>2.2 mV to 7 mV) >20 kHz to 50 kHz
82 ×10-6 U + 2.0 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >50 kHz to 100 kHz
87 ×10-6 U + 2.5 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >100 kHz to 300 kHz
0.23 ×10-3 U + 4.0 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >300 kHz to 500 kHz
0.75 ×10-3 U + 8.0 μVLaboratoryActive
  • (>2.2 mV to 7 mV) >500 kHz to 1 MHz
3.5 ×10-3 U + 8.0 μVLaboratoryActive
  • (>7 mV to 22 mV) 10 Hz to 20 Hz
91 ×10-6 U + 1.3 μVLaboratoryActive
  • (>7 mV to 22 mV) >20 Hz to 40 Hz
56 ×10-6 U + 1.3 μVLaboratoryActive
  • (>7 mV to 22 mV) >40 Hz to 20 kHz
53 ×10-6 U + 1.3 μVLaboratoryActive
  • (>7 mV to 22 mV) >20 kHz to 50 kHz
69 ×10-6 U + 2.0 μVLaboratoryActive
  • (>7 mV to 22 mV) >50 kHz to 100 kHz
78 ×10-6 U + 2.5 μVLaboratoryActive
  • (>7 mV to 22 mV) >100 kHz to 300 kHz
0.17 ×10-3 U + 4.0 μVLaboratoryActive
  • Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
  • (>7 mV to 22 mV) >300 kHz to 500 kHz
0.62 ×10-3 U + 8.0 μVLaboratoryActive
  • (>7 mV to 22 mV) >500 kHz to 1 MHz
2.6 ×10-3 U + 8.0 μVLaboratoryActive
  • (>22 mV to 70 mV) 10 Hz to 20 Hz
85 ×10-6 U + 1.5 μVLaboratoryActive
  • (>22 mV to 70 mV) >20 Hz to 40 Hz
52 ×10-6 U + 1.5 μVLaboratoryActive
  • (>22 mV to 70 mV) >40 Hz to 20 kHz
50 ×10-6 U + 1.5 μVLaboratoryActive
  • (>22 mV to 70 mV) >20 kHz to 50 kHz
54 ×10-6 U + 2.0 μVLaboratoryActive
  • (>22 mV to 70 mV) >50 kHz to 100 kHz
70 ×10-6 U + 2.5 μVLaboratoryActive
  • (>22 mV to 70 mV) >100 kHz to 300 kHz
0.18 ×10-3 U + 4.0 μVLaboratoryActive
  • (>22 mV to 70 mV) >300 kHz to 500 kHz
0.33 ×10-3 U + 8.0 μVLaboratoryActive
  • (>22 mV to 70 mV) >500 kHz to 1 MHz
1.3 ×10-3 U + 8.0 μVLaboratoryActive
  • (>70 mV to 220 mV) 10 Hz to 20 Hz
64 ×10-6 U + 1.5 μVLaboratoryActive
  • (>70 mV to 220 mV) >20 Hz to 40 Hz
36 ×10-6 U + 1.5 μVLaboratoryActive
  • (>70 mV to 220 mV) >40 Hz to 20 kHz
34 ×10-6 U + 1.5 μVLaboratoryActive
  • (>70 mV to 220 mV) >20 kHz to 50 kHz
34 ×10-6 U + 2.0 μVLaboratoryActive
  • (>70 mV to 220 mV) >50 kHz to 100 kHz
60 ×10-6 U + 2.5 μVLaboratoryActive
  • (>70 mV to 220 mV) >100 kHz to 300 kHz
0.18 ×10-3 U + 4.0 μVLaboratoryActive
  • (>70 mV to 220 mV) >300 kHz to 500 kHz
0.32 ×10-3 U + 8.0 μVLaboratoryActive
  • (>70 mV to 220 mV) >500 kHz to 1 MHz
1.2 ×10-3 U + 8.0 μVLaboratoryActive
  • (>220 mV to 700 mV) 10 Hz to 20 Hz
64 ×10-6 U + 1.5 μVLaboratoryActive
  • (>220 mV to 700 mV) >20 Hz to 40 Hz
37 ×10-6 U + 1.5 μVLaboratoryActive
  • (>220 mV to 700 mV) >40 Hz to 20 kHz
34 ×10-6 U + 1.5 μVLaboratoryActive
  • Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
  • (>220 mV to 700 mV) >20 kHz to 50 kHz
34 ×10-6 U + 2.0 μVLaboratoryActive
  • (>220 mV to 700 mV) >50 kHz to 100 kHz
60 ×10-6 U + 2.5 μVLaboratoryActive
  • (>220 mV to 700 mV) >100 kHz to 300 kHz
0.18 ×10-3 U + 4.0 μVLaboratoryActive
  • (>220 mV to 700 mV) >300 kHz to 500 kHz
0.32 ×10-3 U + 8.0 μVLaboratoryActive
  • (>220 mV to 700 mV) >500 kHz to 1 MHz
1.2 ×10-3 U + 8.0 μVLaboratoryActive
  • (>700 mV to 2.2 V) 10 Hz to 20 Hz
64 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >20 Hz to 40 Hz
37 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >40 Hz to 20 kHz
30 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >20 kHz to 50 kHz
34 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >50 kHz to 100 kHz
58 ×10-6 ULaboratoryActive
  • (>700 mV to 2.2 V) >100 kHz to 300 kHz
0.17 ×10-3 ULaboratoryActive
  • Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
  • (>700 mV to 2.2 V) >300 kHz to 500 kHz
0.29 ×10-3 ULaboratoryActive
  • (>700 mV to 2.2 V) >500 kHz to 1 MHz
1.2 ×10-3 ULaboratoryActive
  • (>2.2 V to 7 V) 10 Hz to 20 Hz
63 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >20 Hz to 40 Hz
37 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >40 Hz to 20 kHz
28 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >20 kHz to 50 kHz
36 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >50 kHz to 100 kHz
74 ×10-6 ULaboratoryActive
  • (>2.2 V to 7 V) >100 kHz to 300 kHz
0.18 ×10-3 ULaboratoryActive
  • (>2.2 V to 7 V) >300 kHz to 500 kHz
0.45 ×10-3 ULaboratoryActive
  • (>2.2 V to 7 V) >500 kHz to 1 MHz
1.5 ×10-3 ULaboratoryActive
  • Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
  • (>7 V to 22 V) 10 Hz to 20 Hz
63 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >20 Hz to 40 Hz
38 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >40 Hz to 20 kHz
28 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >20 kHz to 50 kHz
36 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >50 kHz to 100 kHz
70 ×10-6 ULaboratoryActive
  • (>7 V to 22 V) >100 kHz to 300 kHz
0.19 ×10-3 ULaboratoryActive
  • (>7 V to 22 V) >300 kHz to 500 kHz
0.46 ×10-3 ULaboratoryActive
  • (>7 V to 22 V) >500 kHz to 1 MHz
1.5 ×10-3 ULaboratoryActive
  • (>22 V to 70 V) 10 Hz to 20 Hz
64 ×10-6 U + 1.6 μVLaboratoryActive
  • (>22 V to 70 V) >20 Hz to 40 Hz
40 ×10-6 U + 2.6 μVLaboratoryActive
  • (>22 V to 70 V) >40 Hz to 20 kHz
35 ×10-6 U + 2.9 μVLaboratoryActive
  • Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
  • (>22 V to 70 V) >20 kHz to 50 kHz
40 ×10-6 U + 2.6 μVLaboratoryActive
  • (>22 V to 70 V) >50 kHz to 100 kHz
86 ×10-6 U + 1.2 μVLaboratoryActive
  • (>22 V to 70 V) >100 kHz to 300 kHz
0.19 ×10-3 ULaboratoryActive
  • (>22 V to 70 V) >300 kHz to 500 kHz
0.50 ×10-3 ULaboratoryActive
  • (>22 V to 70 V) >500 kHz to 1 MHz
1.5 ×10-3 ULaboratoryActive
  • (>70 V to 220 V) 10 Hz to 20 Hz
66 ×10-6 ULaboratoryActive
  • (>70 V to 220 V) >20 Hz to 40 Hz
42 ×10-6 ULaboratoryActive
  • (>70 V to 220 V) >40 Hz to 20 kHz
37 ×10-6 ULaboratoryActive
  • (>70 V to 220 V) >20 kHz to 50 kHz
51 ×10-6 ULaboratoryActive
  • (>70 V to 220 V) >50 kHz to 100 kHz
89 ×10-6 ULaboratoryActive
  • (>220 V to 700 V) 40 Hz to 20 kHz
34 ×10-6 U + 30 μVLaboratoryActive
  • (>220 V to 700 V) >20 kHz to 50 kHz
0.15 ×10-3 U + 7.2 μVLaboratoryActive
  • (>220 V to 700 V) >50 kHz to 100 kHz
0.86 ×10-3 U + 1.2 μVLaboratoryActive
  • (>700 V to 1000 V) 40 Hz to 20 kHz
34 ×10-6 U + 13 μVLaboratoryActive
  • AC Current Calibration of measuring Instruments
  • Procedure CP-E-11 Calibration of Digital Multimeters I = Measured Value
  • (30 µA to 1 mA) 10 Hz to 20 Hz
75 ×10-6 I + 2.0 nALaboratoryActive
  • (30 µA to 1 mA) >20 Hz to 10 kHz
49 ×10-6 I + 2.0 nALaboratoryActive
  • (30 µA to 1 mA) >10 kHz to 30 kHz
48 ×10-6 I + 3.0 nALaboratoryActive
  • (>1 mA to 10 mA ) 10 Hz to 20 Hz
73 ×10-6 I + 17 nALaboratoryActive
  • (>1 mA to 10 mA ) >20 Hz to 10 kHz
45 ×10-6 I + 16 nALaboratoryActive
  • (>1 mA to 10 mA ) >10 kHz to 30 kHz
45 ×10-6 I + 22 nALaboratoryActive
  • (>10 mA to 50 mA ) 10 Hz to 20 Hz
73 ×10-6 I + 83 nALaboratoryActive
  • (>10 mA to 50 mA ) >20 Hz to 10 kHz
47 ×10-6 I + 75 nALaboratoryActive
  • (>10 mA to 50 mA ) >10 kHz to 30 kHz
46 ×10-6 I + 0.11 μALaboratoryActive
  • (>50 mA to 500 mA ) 10 Hz to 20 Hz
75 ×10-6 I + 0.81 μALaboratoryActive
  • (>50 mA to 500 mA ) >20 Hz to 10 kHz
50 ×10-6 I + 0.73 μALaboratoryActive
  • (>50 mA to 500 mA ) >10 kHz to 30 kHz
49 ×10-6 I + 1.0 μALaboratoryActive
  • (>500 mA to 1 A ) 10 Hz to 20 Hz
80 ×10-6 I + 1.5 μALaboratoryActive
  • (>500 mA to 1 A ) >20 Hz to 10 kHz
57 ×10-6 I + 1.2 μALaboratoryActive
  • Procedure CP-E-11 Calibration of Digital Multimeters I = Measured Value
  • (>1 A to 5 A ) 10 Hz to 20 Hz
83 ×10-6 I + 7.4 μALaboratoryActive
  • (>1 A to 5 A ) >20 Hz to 10 kHz
60 ×10-6 I + 5.9 μALaboratoryActive
  • (>5 A to 20 A ) 10 Hz to 20 Hz
0.12 ×10-3 I + 21 μALaboratoryActive
  • (>5 A to 20 A ) >20 Hz to 10 kHz
0.11 ×10-3 I + 14 μALaboratoryActive
  • (>20 A to 50 A) 20 Hz to 10 kHz
0.14 ×10-3 I + 27 μALaboratoryActive
  • AC Current calibration of sources
  • Procedure CP-E-18 Calibration of Electrical Calibrators I = Measured Value
  • (30 µA to 1 mA) 10 Hz to 20 Hz
75 ×10-6 I + 2.0 nALaboratoryActive
  • (30 µA to 1 mA) >20 Hz to 10 kHz
49 ×10-6 I + 2.0 nALaboratoryActive
  • (30 µA to 1 mA) >10 kHz to 30 kHz
48 ×10-6 I + 3.0 nALaboratoryActive
  • (>1 mA to 10 mA ) 10 Hz to 20 Hz
73 ×10-6 I + 17 nALaboratoryActive
  • (>1 mA to 10 mA ) >20 Hz to 10 kHz
45 ×10-6 I + 16 nALaboratoryActive
  • (>1 mA to 10 mA ) >10 kHz to 30 kHz
45 ×10-6 I + 22 nALaboratoryActive
  • (>10 mA to 50 mA ) 10 Hz to 20 Hz
73 ×10-6 I + 83 nALaboratoryActive
  • (>10 mA to 50 mA ) >20 Hz to 10 kHz
47 ×10-6 I + 75 nALaboratoryActive
  • (>10 mA to 50 mA ) >10 kHz to 30 kHz
46 ×10-6 I + 0.11 μALaboratoryActive
  • (>50 mA to 500 mA ) 10 Hz to 20 Hz
75 ×10-6 I + 0.83 μALaboratoryActive
  • (>50 mA to 500 mA ) >20 Hz to 10 kHz
50 ×10-6 I + 0.75 μALaboratoryActive
  • (>50 mA to 500 mA ) >10 kHz to 30 kHz
49 ×10-6 I + 1.1 μALaboratoryActive
  • (>500 mA to 1 A ) 10 Hz to 20 Hz
80 ×10-6 I + 1.5 μALaboratoryActive
  • (>500 mA to 1 A ) >20 Hz to 10 kHz
57 ×10-6 I + 1.2 μALaboratoryActive
  • (>1 A to 5 A ) 10 Hz to 20 Hz
83 ×10-6 I + 7.5 μALaboratoryActive
  • (>1 A to 5 A ) >20 Hz to 10 kHz
60 ×10-6 I + 6.0 μALaboratoryActive
  • (>5 A to 20 A ) 10 Hz to 20 Hz
0.12 ×10-3 I + 21 μALaboratoryActive
  • (>5 A to 20 A ) >20 Hz to 10 kHz
0.11 ×10-3 I + 15 μALaboratoryActive
  • (>20 A to 50 A) 20 Hz to 10 kHz
0.14 ×10-3 I + 27 μALaboratoryActive
  • DC resistance Calibration of Instruments
  • Procedure CP-E-14 Calibration of Temperature Readouts Procedure CP-E-16 Calibration of Fluke Super Thermometer Procedure CP-E-06 Calibration of 8.5 digit Digital Multimeters
  • 0 Ω
3.0 μΩLaboratoryActive
  • 1 Ω
3.8 μΩLaboratoryActive
  • 10 Ω
9.1 μΩLaboratoryActive
  • 25 Ω
32 μΩLaboratoryActive
  • 100 Ω
0.10 mΩLaboratoryActive
  • 200 Ω
0.26 mΩLaboratoryActive
  • 400 Ω
0.52 mΩLaboratoryActive
  • DC Resistance calibration of Measuring Instruments
  • Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-24 Calibration of Process Calibrators R = Measured Value
  • 0 Ω to 2 Ω
42×10-6 R + 4.1 µΩLaboratoryActive
  • >2 Ω to 11 Ω
41×10-6 R + 5.0 µΩLaboratoryActive
  • >11 Ω to 33 Ω
31×10-6 R + 18 µΩLaboratoryActive
  • >33 Ω to 110 Ω
29×10-6 R + 18 µΩLaboratoryActive
  • >110 Ω to 330 Ω
29 ×10-6 R + 0.18 mΩLaboratoryActive
  • >330 Ω to 1.1 kΩ
29 ×10-6 R + 0.18 mΩLaboratoryActive
  • Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-24 Calibration of Process Calibrators R = Measured Value
  • >1.1 kΩ to 3.3 kΩ
29 ×10-6 R + 1.7 mΩLaboratoryActive
  • >3.3 kΩ to 11 kΩ
29 ×10-6 R + 1.4 mΩLaboratoryActive
  • >11 kΩ to 33 kΩ
29 ×10-6 R + 17 mΩLaboratoryActive
  • >33 kΩ to 110 kΩ
30 ×10-6 R + 15 mΩLaboratoryActive
  • >110 kΩ to 330 kΩ
34 ×10-6 R + 25 mΩLaboratoryActive
  • >300 kΩ to 1.1 MΩ
34 ×10-6 R + 25 mΩLaboratoryActive
  • >1.1 MΩ to 3.3 MΩ
62 ×10-6 R + 2.3 ΩLaboratoryActive
  • >3.3 MΩ to 11 MΩ
0.13 ×10-3 R + 0.92 ΩLaboratoryActive
  • >11 MΩ to 33 MΩ
0.16 ×10-3 R + 9.0 kΩLaboratoryActive
  • >33 MΩ to 110 MΩ
0.48 ×10-3 R + 4.2 kΩLaboratoryActive
  • >110 MΩ to 330 MΩ
3.0 ×10-3 R + 20 kΩLaboratoryActive
  • >330 MΩ to 1 GΩ
15 ×10-3 R + 2.1 kΩLaboratoryActive
  • DC Resistance calibration of sources
  • Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-23 Calibration of Resistor Decades Procedure CP-E-24 Calibration of Process Calibrators R = Measured Value
  • 0 Ω to 2 Ω
13 ×10-6 R + 4.0 μΩLaboratoryActive
  • >2 Ω to 20 Ω
7.9 ×10-6 R + 14 μΩLaboratoryActive
  • >20 Ω to 200 Ω
7.4 ×10-6 R + 49 μΩLaboratoryActive
  • >0.2 Ω to 2 kΩ
7.2 ×10-6 R + 0.50 mΩLaboratoryActive
  • >2 kΩ to 20 kΩ
7.3 ×10-6 R + 4.9 mΩLaboratoryActive
  • >20 kΩ to 200 kΩ
7.6 ×10-6 R + 48 mΩLaboratoryActive
  • >0.2 MΩ to 2 MΩ
8.4 ×10-6 R + 85 mΩLaboratoryActive
  • >2 MΩ to 20 MΩ
12 ×10-6 R + 8.3 ΩLaboratoryActive
  • >20 MΩ to 200 MΩ
46 ×10-6 R + 9.8 kΩLaboratoryActive
  • >0.2 GΩ to 2 GΩ
68 ×10-6 R + 94 kΩLaboratoryActive
  • >2 GΩ to 20 GΩ
0.56 ×10-3 R +0.96 MΩLaboratoryActive
  • DC Current Calibration of Measuring Instruments
  • Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-24 Calibration of Process Calibrators I = Measured Value
  • 0 µA to 100 µA
4.0 ×10-6 I + 49 pALaboratoryActive
  • >100 µA to 1 mA
4.0 ×10-6 I + 0.49 nALaboratoryActive
  • >1 mA to 10 mA
4.0 ×10-6 I + 4.9 nALaboratoryActive
  • >10 mA to 100 mA
2.3×10-6 I + 0.65 μALaboratoryActive
  • >0.1 A to 1 A
35 ×10-6 I + 4.2 μALaboratoryActive
  • >1 A to 5 A
38 ×10-6 I + 0.88 μALaboratoryActive
  • >5 A to 20 A
38×10-6 I + 16 μALaboratoryActive
  • DC Current Calibration of sources
  • Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators I = Measured Value
  • 0 µA to 100 µA
4.0 ×10-6 I + 49 pALaboratoryActive
  • >100 µA to 1 mA
4.0 ×10-6 I + 0.49 nALaboratoryActive
  • >1 mA to 10 mA
4.0 ×10-6 I + 4.9 nALaboratoryActive
  • >10 mA to 100 mA
2.3×10-6 I + 0.65 μALaboratoryActive
  • >0.1 A to 1 A
35 ×10-6 I + 4.2 μALaboratoryActive
  • >1 A to 5 A
38 ×10-6 I + 0.88 μALaboratoryActive
  • >5 A to 20 A
38×10-6 I + 16 μALaboratoryActive
  • Procedure CP-E-22 Calibration of Current Source I = measured current value
  • >1 A to 10 A
17 ×10-6 ILaboratoryActive
  • >10 A to 150 A
20 ×10-6 ILaboratoryActive
  • Temperature Calibration of measuring instruments by simulation
  • Procedure CP-E-14 Calibration of Temperature Readouts Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators
  • (RTD: (PT100 (385)) -270 °C to 860 °C
0.010 °CLaboratoryActive
  • (THERMOCOUPLE: (Type J)) -200 °C to <-100 °C
0.15 °CLaboratoryActive
  • (THERMOCOUPLE: (Type J)) -100 °C to 1000 °C
0.14 °CLaboratoryActive
  • (Type K) -200 °C to <-100 °C
0.16 °CLaboratoryActive
  • (Type K) -100 °C to 1000 °C
0.13 °CLaboratoryActive
  • Procedure CP-E-14 Calibration of Temperature Readouts Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators
  • (THERMOCOUPLE: (Type N) -200 °C to <-100 °C
0.20 °CLaboratoryActive
  • (THERMOCOUPLE: (Type N) -100 °C to 1300 °C
0.15 °CLaboratoryActive
  • (Type R) 0 °C to <100 °C
0.33 °CLaboratoryActive
  • (Type R) 100 °C to <500 °C
0.23 °CLaboratoryActive
  • (Type R) 500 °C to <1000 °C
0.19 °CLaboratoryActive
  • (Type R) 1000 °C to 1700 °C
0.18 °CLaboratoryActive
  • (Type S) 0 °C to <100 °C
0.33 °CLaboratoryActive
  • (Type S) 100 °C to <500 °C
0.25 °CLaboratoryActive
  • (Type S) 500 °C to <1000 °C
0.20 °CLaboratoryActive
  • (Type S) 1000 °C to 1700 °C
0.19 °CLaboratoryActive
  • (THERMOCOUPLE: (Type T) -200 °C to <-100 °C
0.17 °CLaboratoryActive
  • (THERMOCOUPLE: (Type T) -100 °C to <0 °C
0.15 °CLaboratoryActive
  • (THERMOCOUPLE: (Type T) 0 °C to 400 °C
0.14 °CLaboratoryActive
  • Temperature Calibration of simulators
  • Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators
  • (RTD: (PT100 (385)) -270 °C to 860 °C
0.014 °CLaboratoryActive
  • (THERMOCOUPLE: (Type J) -200 °C to <-100 °C
0.11 °CLaboratoryActive
  • (THERMOCOUPLE: (Type J) -100 °C to <0 °C
0.091 °CLaboratoryActive
  • (THERMOCOUPLE: (Type J) 0 °C to 1200 °C
0.089 °CLaboratoryActive
  • Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators
  • (THERMOCOUPLE: (Type K) -200 °C to <-100 °C
0.13 °CLaboratoryActive
  • (THERMOCOUPLE: (Type K) -100 °C to <0 °C
0.096 °CLaboratoryActive
  • (THERMOCOUPLE: (Type K) 0 °C to 1250 °C
0.093 °CLaboratoryActive
  • (Type N) -200 °C to <-100 °C
0.17 °CLaboratoryActive
  • (Type N) -100 °C to <100 °C
0.11 °CLaboratoryActive
  • (Type N) 100 °C to 1300 °C
0.096 °CLaboratoryActive
  • (Type R) 0 °C to <100 °C
0.32 °CLaboratoryActive
  • (Type R) 100 °C to <500 °C
0.20 °CLaboratoryActive
  • (Type R) 500 °C to <1000 °C
0.16 °CLaboratoryActive
  • (Type R) 1000 °C to 1700 °C
0.14 °CLaboratoryActive
  • (THERMOCOUPLE: (Type S) 0 °C to <100 °C
0.30 °CLaboratoryActive
  • (THERMOCOUPLE: (Type S) 100 °C to <500 °C
0.22 °CLaboratoryActive
  • (THERMOCOUPLE: (Type S) 500 °C to <1000 °C
0.17 °CLaboratoryActive
  • (THERMOCOUPLE: (Type S) 1000 °C to 1700 °C
0.15 °CLaboratoryActive
  • (Type T) -200 °C to <-100 °C
0.092 °CLaboratoryActive
  • (Type T) -100 °C to <0 °C
0.097 °CLaboratoryActive
  • (Type T) 0 °C to <100 °C
0.093 °CLaboratoryActive
  • (Type T) 100 °C to 400 °C
0.089 °CLaboratoryActive
  • CAPACITANCE Calibration of Measuring Instruments
  • Procedure CP-E-11 Calibration of Digital Multimeters C = Measured Value
  • 220 pF to 3 nF
5.0 ×10-3 C + 11 pFLaboratoryActive
  • >3 nF to 10 nF
2.5 ×10-3 C + 11 pFLaboratoryActive
  • >10 nF to 30 nF
2.5 ×10-3 C + 0.11 nFLaboratoryActive
  • >30 nF to 100 nF
2.5 ×10-3 C + 0.11 nFLaboratoryActive
  • >100 nF to 300 nF
2.5 ×10-3 C + 0.31 nFLaboratoryActive
  • >300 nF to 1 µF
2.5 ×10-3 C + 1.1 nFLaboratoryActive
  • >1 µF to 3 µF
2.5 ×10-3 C + 3.1 nFLaboratoryActive
  • >3 µF to 10 µF
2.4 ×10-3 C + 14 nFLaboratoryActive
  • >10 µF to 30 µF
3.9 ×10-3 C +38 nFLaboratoryActive
  • >30 µF to 100 µF
4.3 ×10-3 C + 0.14 µFLaboratoryActive
  • >100 µF to 300 µF
4.3 ×10-3 C + 0.41 µFLaboratoryActive
  • >300 µF to 1 mF
4.4 ×10-3 C + 1.2 µFLaboratoryActive
  • >1 mF to 3 mF
4.5 ×10-3 C + 3.1 µFLaboratoryActive
  • >3 mF to 10 mF
4.5 ×10-3 C + 11 µFLaboratoryActive
  • >10 mF to 30 mF
7.5 ×10-3 C + 31 µFLaboratoryActive
  • >30 mF to 110 mF
11 ×10-3 C + 12 µFLaboratoryActive
  • Capacitance calibration of sources
  • Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-28 Calibration of Capacitors and Inductors
  • 220 pF to 3 nF
1.4 pFLaboratoryActive
  • >3 nF to 10 nF
2.9 pFLaboratoryActive
  • >10 nF to 30 nF
7.7 pFLaboratoryActive
  • >30 nF to 100 nF
25 pFLaboratoryActive
  • >100 nF to 300 nF
76 pFLaboratoryActive
  • >300 nF to 1 µF
0.26 nFLaboratoryActive
  • >1 µF to 3 µF
0.78 nFLaboratoryActive
  • >3 µF to 10 µF
11 nFLaboratoryActive
  • >10 µF to 30 µF
31 nFLaboratoryActive
  • >30 µF to 100 µF
0.12 µFLaboratoryActive
  • >100 µF to 300 µF
0.37 µFLaboratoryActive
  • >300 µF to 1 mF
0.87 µFLaboratoryActive
  • >1 mF to 3 mF
0.87 µFLaboratoryActive
  • >3 mF to 10 mF
2.9 µFLaboratoryActive
  • >10 mF to 30 mF
9.5 µFLaboratoryActive
  • >30 mF to 110 mF
33 µFLaboratoryActive
  • Standard capacitors
  • Procedure CP-E-28 Calibration of Capacitors and Inductors Substitution method at 1 kHz C = Measured Value
  • 10 pF
20 ×10-6 CLaboratoryActive
  • 100 pF
20 ×10-6 CLaboratoryActive
  • 1 nF
20 ×10-6 CLaboratoryActive
  • Standard inductors
  • Procedure CP-E-28 Calibration of Capacitors and Inductors Substitution method at 1 kHz L= Measured Value
  • 100 µH
0.75 ×10-3 LLaboratoryActive
  • 1 mH
0.14 ×10-3 LLaboratoryActive
  • 10 mH
0.26 ×10-3 LLaboratoryActive
  • 100 mH
0.27 ×10-3 LLaboratoryActive
  • 1 H
0.26 ×10-3 LLaboratoryActive
  • Inductance Calibration of Sources
  • Procedure CP-E-28 Calibration of Capacitors and Inductors L= Measured Value
  • 1 mH to 10 mH
1.1 ×10-3 LLaboratoryActive
  • >10 mH to 1 H
0.80 ×10-3 LLaboratoryActive
  • AC power Calibration of power meters
  • Procedure CP-E-30 Primary Power Measurements
  • 1 V to 500 V
Active powerLaboratoryActive
  • 0.125 A to 120 A
25 μW/VALaboratoryActive
  • 45 Hz to 65 Hz
Reactive powerLaboratoryActive
  • Power factor 0 to 1
40 μvar/VALaboratoryActive
  • AC power Calibration of phantom power sources
  • 1 V to 500 V
Active PowerLaboratoryActive
  • 0.125 A to 200 A
25 μW/ VALaboratoryActive
  • 45 Hz to 65 Hz
Reactive PowerLaboratoryActive
  • Power factor 0 to 1
40 μvar/ VALaboratoryActive
  • AC energy Calibration of energy meters
  • 1 V to 500 V
Active PowerLaboratoryActive
  • 0.125 A to 120 A
25 μWh/ VAhLaboratoryActive
  • 45 Hz to 65 Hz
Reactive PowerLaboratoryActive
  • Power factor 0 to 1
40 μvarh/ VAhLaboratoryActive
  • AC energy Calibration of phantom energy sources
  • 1 V to 500 V
Active PowerLaboratoryActive
  • 0.125 A to 200 A
25 μWh/ VAhLaboratoryActive
  • 45 Hz to 65 Hz
Reactive PowerLaboratoryActive
  • Power factor 0 to 1
40 μvarh/ VAhLaboratoryActive
  • AC energy Calibration of energy meters
  • Procedure CP-E-31 Power Measurements class 0.1 and above
  • 30 V to 490 V
Active energyLaboratoryActive
  • 4 mA to 120 A
260 μWh/VAhLaboratoryActive
  • 45 Hz to 65 Hz
Reactive energyLaboratoryActive
  • Power factor 0 to 1
270 μvarh/VahLaboratoryActive
  • AC Current Ratio Calibration of Isolating Current Transformer
  • Procedure CP-E-34 Calibration of Isolating Current Transformer
  • Ratio 1:1 1 A to 100 A
Ratio Error UncertaintyLaboratoryActive
0.18 ×10-3LaboratoryActive
Defect Angle UncertaintyLaboratoryActive
0.11 °LaboratoryActive
Density
  • Solid Density Standard at 20°C Mass: 1 kg
  • CP-V-05 “Solid density by Hydrostatic weighing” Hydrostatic weighing (comparison to reference silicon sphere SP-1)
  • 2330 kg/m3
1.5 kg/m3LaboratoryActive
  • Density of solid at 20°C Mass: 20g to 30g
  • CP-V-05 “Solid density by Hydrostatic weighing” Hydrostatic weighing with use of volume comparator
  • 2300 kg/m3 to 2800 kg/m3
1 kg/ m3LaboratoryActive
  • Density of solid at 20°C Mass: 1g to 1kg Density: 7900 kg/m3 to 8400 kg/m3
  • 1g
60 kg/m3LaboratoryActive
  • 2 g
30 kg/m3LaboratoryActive
  • 5 g
15 kg/m3LaboratoryActive
  • 10 g
8 kg/m3LaboratoryActive
  • 20 g
5 kg/m3LaboratoryActive
  • 50 g
3 kg/m3LaboratoryActive
  • 100 g
2.5 kg/m3LaboratoryActive
  • 200 g
2 kg/m3LaboratoryActive
  • 500 g
2 kg/m3LaboratoryActive
  • 1 kg
1.5 kg/m3LaboratoryActive
  • Density of Liquid at 20°C
  • CP-V-04 Hydrostatic weighing with use of glass sinker of appr. . ca. 25g mass
  • 680 kg/m3 to 1200 kg/m3
0.86 kg/m3 to 1.3 kg/m3LaboratoryActive
Volume
  • Volume of Liquids Piston operated volumetric apparatus (pipettes, dispensers)
  • CP-V-01 “Gravimetric Calibration of piston operated pipettes” Fixed and variable volume single and multi-channel Manual or automatic piston operated pipettes using gravimetric method: - 1 volume (fixed volume pipettes) - 3 volumes (variable volume pip
  • 10 µl
0.024 µlLaboratoryActive
  • 20 µl
0.028 µlLaboratoryActive
  • 50 µl
0.046 µlLaboratoryActive
  • 100 µl
0.083 µlLaboratoryActive
  • 200 µl
0.17 µlLaboratoryActive
  • 500 µl
0.41 µlLaboratoryActive
  • 1000 µl
2.1 µlLaboratoryActive
  • 2000 µl
5 µlLaboratoryActive
  • 5000 µl
8 µlLaboratoryActive
  • 10000 µl
17 µlLaboratoryActive
  • Volumetric glassware One-mark flasks
  • CP-V-02 “Gravimetric Calibration of Volumetric Glassware”
  • 10 ml
0.023 mlLaboratoryActive
  • 20 ml
0.033 mlLaboratoryActive
  • 50 ml
0.047 mlLaboratoryActive
  • 100 ml
0.064 mlLaboratoryActive
  • 200 ml
0.087 mlLaboratoryActive
  • 500 ml
0.13 mlLaboratoryActive
  • 1000 ml
0.19 mlLaboratoryActive
  • Volumetric glassware Graduated measuring cylinders
  • 10 ml
0.070 mlLaboratoryActive
  • 20 ml
0.12 mlLaboratoryActive
  • 50 ml
0.21 mlLaboratoryActive
  • 100 ml
0.38 mlLaboratoryActive
  • 200 ml
0.60 mlLaboratoryActive
  • 500 ml
0.84 mlLaboratoryActive
  • 1000 ml
1.5 mlLaboratoryActive
  • 2000 ml
2.5 mlLaboratoryActive
  • Volumetric glassware Pipettes
  • 1 ml
0.0060 mlLaboratoryActive
  • 2 ml
0.0060 mlLaboratoryActive
  • 5 ml
0.012 mlLaboratoryActive
  • 10 ml
0.018 mlLaboratoryActive
  • 25 ml
0.040 mlLaboratoryActive
  • Volumetric glassware Burettes
  • 10 ml
0.020 mlLaboratoryActive
  • 25 ml
0.020 mlLaboratoryActive
  • 50 ml
0.040 mlLaboratoryActive
  • 100 ml
0.070 mlLaboratoryActive
  • Metallic prover vessels
  • CP-V-03 “Gravimetric Calibration of Prover Vessels”
  • 5 L to 100 L
0.001LaboratoryActive
Dimensions
  • Gauge Block (mm)(steel, ceramic, Tungsten) carbide)
  • Measurement of central length by interferometry. Measured twice, wrung to a platen by each of the two measuring faces in turn, and the mean of these two measurements stated on the certificate. Procedure used: EMI Procedure no.: CP-D-09 ISO 3650:1998
  • 0.5 mm to 100 mm, Grade K and Grade 0
Q[25 nm, 0.7×10-6 L]LaboratoryActive
  • Long Gauge Block (mm) (steel, ceramic, Tungsten)
  • Measurement of central length by interferometry. Measured twice, wrung to a platen by each of the two measuring faces in turn, and the mean of these two measurements stated on the certificate. Procedure used: EMI Procedure no.: CP-D-09 ISO 3650:1998
  • 100 mm to 300 mm Grade K and Grade 0
Q[37 nm, 0.7×10-6 L]LaboratoryActive
  • Gauge Block (mm) steel
  • Measurement of central length by mechanical comparison. Procedure used: EMI procedure no.: CP-D-03 ISO 3650:1998
  • 0.5 mm to 100 mm
Q[80 nm, 1.1×10-6 L]LaboratoryActive
  • Gauge Block (mm) ceramic
Q[80 nm, 1.93×10-6 L]LaboratoryActive
  • Long Gauge Block
  • Measurement of central length by mechanical comparison to same nominal size long gauge blocks using universal length measuring machine Procedure used: EMI procedure no.: CP-D-06 ISO 3650:1998
  • 125 mm to 500 mm
Q[0.16 μm, 1.9×10-6 L]LaboratoryActive
  • Gauge Blocks Comparator
  • For determining error of indicated displacement Mechanical comparison to gauge block couples Procedure used: EMI procedure no.: CP-D-12 EURAMET cg-2 Version 2.0 (03/2011) (Previously EA-10/02)
  • 0.5 mm to 100 mm
0.05 μmLaboratoryActive
  • 1-D measuring Machine (Universal Length Measuring Machine)
  • For determining error of indicated size/displacement Mechanical comparison to gauge block Procedure used: EMI procedure no.: CP-D-13
  • upto 100 mm
Q[0.062 μm, 1.3×10-6 L]LaboratoryActive
  • Height Gauges (analoges, digitals)
  • For determining error of indicated vertical size Comparison with calliper checker Procedure used: EMI Procedure no.: CP-D-05 ISO 13225:2012
  • upto 600 mm, resolution 0.01 mm
(0.02 mm + 1×10-5L)LaboratoryActive
  • Angle Gauges
  • Measurement of included angle by comparison to primary encoder. Procedure used: EMI Procedure no.: CP-D-15
  • upto 90º
0.6"LaboratoryActive
  • Angle Indicating Instruments
  • For determining error of indicated inclination angle Comparison to primary encoder in vertical orientation Procedure used: EMI procedure no.: CP-D-16
  • upto 90º, resolution 0.01º
0.01°LaboratoryActive
  • Dial Gauges
  • For determining error of indicated displacement, Comparison with universal length measuring machine Procedure used: EMI procedure no.: CP-D-02 ISO 463:2006
  • up to 50 mm, resolution 0.001 mm
2µmLaboratoryActive
  • 50 mm to 100mm, resolution 0.001 mm
3µmLaboratoryActive
  • External Micrometes
  • For determining error of indicated size Comparison with reference gauge blocks Comparison with universal length measuring machine. Procedure used: EMI procedure no.: CP-D-01 ISO 3611:2010
  • 0 mm to 25mm, resolution 0.001 mm
2µmLaboratoryActive
  • 25 mm to 75mm resolution 0.001 mm
2µmLaboratoryActive
  • 75 mm to 175mm resolution 0.001 mm
3µmLaboratoryActive
  • External Cylinder, Plain Plug Gauges (parallel) and Pin Gauges
  • Comparison with reference gauge block using universal length measuring machine. Procedure used: EMI Procedure no.: CP-D-07 EURAMET cg-6 Version 2.0 (03/2011)
  • 1 mm to 80 mm diameter
0.8 µmLaboratoryActive
  • Internall Cylinder, Plain Ring Gauges (parallel)
  • Comparison with reference ring gauge using universal length measuring machine. Procedure used: EMI Procedure no.: CP-D-08 EURAMET cg-6 Version 2.0 (03/2011)
  • 10 mm to 100 mm diameter
0.8 µmLaboratoryActive
  • Calipers (digital, vernier)
  • For determining error of indicated size Comparison with calliper checker and gauge blocks (for callipers with vernier scale). Procedure used: EMI procedure no.: CP-D-04 ISO 13385-1:2019
  • up to 600 mm resolution 0.01 mm
(0.02 mm + 1.2×10-5 L)LaboratoryActive
Force
  • Force / Force Proving Instruments (tension and compression mode)
  • Calibration of force proving instruments in accordance with ISO 376:2011 increasing and decreasing forces
  • 100 kN to 5000 kN
0.05% of indicated valueLaboratoryActive
  • 50 kN to 100 kN
0,1 % of indicated valueLaboratoryActive
Pressure
  • Pneumatic Negative Gauge Analogue and digital pressure gauges
  • CP-P-01 SOP based on DKD-R 6-1 and Euramet cg17
  • -92 kPa to -10 kPa
3 Pa + 1.6x10-3*pLaboratoryActive
  • Pneumatic Differential Pressure Analogue and digital pressure gauges
  • -92 kPa to 280 kPa
3 Pa + 1.6x10-3*pLaboratoryActive
  • Pneumatic Gauge and Absolute Pressure Analogue and digital pressure gauges
  • 9.0 kPa to 700 kPa
2 Pa+2.0x10-5*p8.024Active
  • > 0.7 MPa to 3.5 MPa
3.5 Pa+2.5x10-5*pLaboratoryActive
  • > 3.5 MPa to 7 MPa
10 Pa+3.0x10-5*pLaboratoryActive
  • Hydraulic Gauge Pressure Analogue and digital pressure gauges
  • 1 MPa to 100 MPa
0.10 kPa+4.2x10-5*pLaboratoryActive
  • > 100 MPa to 280 MPa
1,610-4*pLaboratoryActive